<?xml version="1.0" standalone="no"?>
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA81/3.2">
  <GAEBInfo>
    <Version>3.2</Version>
    <VersDate>2013-10</VersDate>
    <Date>2025-09-16</Date>
    <Time>17:33:53</Time>
    <ProgSystem>RP-Group PIM-System</ProgSystem>
    <ProgName>PIM GAEB-Konverter 1.0</ProgName>
  </GAEBInfo>
  <PrjInfo>
    <NamePrj>Prj-Name</NamePrj>
    <LblPrj>Projektbezeichnung</LblPrj>
    <Descrip>
      <p style="text-align:left;">
        <span style="font-family:'Arial';font-size:10pt;">Projektbeschreibung</span>
      </p>
    </Descrip>
    <Cur>EUR</Cur>
    <CurLbl>Euro</CurLbl>
    <UPFracDig>2</UPFracDig>
  </PrjInfo>
  <Award>
    <DP>81</DP>
    <AwardInfo>
      <Cur>EUR</Cur>
      <CurLbl>Euro</CurLbl>
    </AwardInfo>
    <BoQ ID="ID242">
      <BoQInfo>
        <Name>LV-Name</Name>
        <LblBoQ>LV-Bezeichnung</LblBoQ>
        <Date>2025-09-16</Date>
        <OutlCompl>AllTxt</OutlCompl>
        <BoQBkdn>
          <Type>Item</Type>
          <Length>1</Length>
          <Num>Yes</Num>
        </BoQBkdn>
        <LblTime>Stunden</LblTime>
      </BoQInfo>
      <BoQBody>
        <Itemlist>
          <Item ID="ID243" RNoPart="1">
            <Qty>1.000</Qty>
            <QU>Stk</QU>
            <Description>
              <CompleteText>
                <DetailTxt>
                  <Text>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">MidiControl</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">MC central emergency power supply system without power limitation in accordance with</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">EN 50171 and BGV A3 for supplying 230V/216V AC/DC safety and escape sign luminaires. Suitable for emergency lighting systems in accordance with DIN VDE 0100-718, DIN VDE 0100-560, DIN EN 50172, and DIN V VDE V 0108-100.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">With automatic test device and individual luminaire monitoring with individual status display for each luminaire in the control unit in conjunction with system-specific electronic ballasts including a monitoring module without an additional data line.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Rated operating time *: 1h; 3h; 8h * Please underline where applicable!</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">... Recharging time: 12 hours</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Consists of:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Microprocessor control unit with DB25 Centronics printer interface and integrated IO module for reporting operating states and remote triggering of function tests and emergency light blocking.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Charging device with microprocessor-controlled charging for standard-compliant battery charging.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- For accommodating up to 32 variable circuit assemblies, as well as a maximum of 2 charging assemblies of 2.5A (5A) each.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Sheet steel combination cabinet, with partially sealed electronics and battery compartments for up to 18 OGIV batteries, up to 55Ah.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Dimensions: H = 1950 mm, W = 600 mm, D = 450 mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Protection class: Electronics cabinet IP 21, Protection Class I</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Including base height 50 mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Cable entry: Standard from the top</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Exterior finish: Textured powder coating</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Color: RAL 7035 light gray</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Equipped with:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- pcs. Charging modules with 2.5A each for standard charging according to the battery.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Freely programmable final circuits with 4A nominal current / max. connected load per circuit 850 VA, two-pole fuse protection (2x T6.3A fuse protection), and information buttons on the front.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Integrated SAM08 light switch interrogation for the joint switching of emergency and general lighting, with 8 switch inputs</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Integrated CCIF module for monitoring the closed-circuit current loop for open circuits and short circuits</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Integrated IO module for reporting faults via 7 potential-free changeover contacts (230V AC/6A) and 4 control inputs 18V - 250V DC or</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">180V - 250V AC</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Battery system equipped with:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Stationary, maintenance-free, sealed, and extremely low-gassing</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Pb battery system according to VDE 0510 DIN EN 50272-2. Service life according to EUROBAT</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">10 years+. Includes all necessary accessories, such as fully insulated connectors, terminal covers, and operating and handling instructions.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- OGiV - Block battery .. Ah / K10 1.8V/Z, 20°C 216V</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">(incl. 25% aging reserve according to EUROBAT and DIN EN 50171)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- SAM08 light switch interrogation module for the joint switching of emergency and general lighting, with 8 switch inputs 185-230 VAC; two possible switching outputs for illuminating push buttons of a time-controlled staircase lighting circuit in battery operation in guest houses/accommodations, hotels, health/care/therapy centers/facilities, and high-rise buildings where the rated operating time of the power source for safety purposes is only 3 hours according to DIN V VDE V 0108-100 or DIN VDE 0100-560; supplied loose ... SAM24 light switch interrogation module for the joint switching of emergency and general lighting, with 8 switch inputs 18-250 VDC or 185-230 VAC; supplied loose</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- MC-LM bus-capable three-phase mains monitoring for installation in general lighting sub-distribution boards</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- MCT15(S) remote signaling device, bus-monitored remote signaling panel</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">According to DIN VDE 0100-718, DIN VDE 0100-560, DIN EN 50172, and DIN V VDE V 0108-100, in an impact-resistant plastic housing for alarms and notification of system statuses via LEDs and plain text.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">In addition, the system can be switched to ready mode or charging mode using a built-in key switch (S), and the continuous lighting circuits can be switched to standby mode using a push button.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Order No.: MD 1;2)/(4;6;8;10;12..32)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Manufacturer: RP-Technik GmbH Emergency Lighting Systems</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Item No.: MD1(2) (4 | 6 | 8 | 10 | 12.. 32)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Unit: pcsBrand: RP-Technik GmbH</span>
</p>
                  </Text>
                </DetailTxt>
                <OutlineText>
                  <OutlTxt>
                    <TextOutlTxt>
                      <p style="text-align:left;">
                        <span style="font-family:'Arial';font-size:10pt;">MD132</span>
                      </p>
                    </TextOutlTxt>
                  </OutlTxt>
                </OutlineText>
              </CompleteText>
            </Description>
          </Item>
        </Itemlist>
      </BoQBody>
    </BoQ>
  </Award>
</GAEB>
