<?xml version="1.0" standalone="no"?>
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA81/3.2">
  <GAEBInfo>
    <Version>3.2</Version>
    <VersDate>2013-10</VersDate>
    <Date>2026-07-14</Date>
    <Time>05:19:52</Time>
    <ProgSystem>RP-Group PIM-System</ProgSystem>
    <ProgName>PIM GAEB-Konverter 1.0</ProgName>
  </GAEBInfo>
  <PrjInfo>
    <NamePrj>Prj-Name</NamePrj>
    <LblPrj>Projektbezeichnung</LblPrj>
    <Descrip>
      <p style="text-align:left;">
        <span style="font-family:'Arial';font-size:10pt;">Projektbeschreibung</span>
      </p>
    </Descrip>
    <Cur>EUR</Cur>
    <CurLbl>Euro</CurLbl>
    <UPFracDig>2</UPFracDig>
  </PrjInfo>
  <Award>
    <DP>81</DP>
    <AwardInfo>
      <Cur>EUR</Cur>
      <CurLbl>Euro</CurLbl>
    </AwardInfo>
    <BoQ ID="ID242">
      <BoQInfo>
        <Name>LV-Name</Name>
        <LblBoQ>LV-Bezeichnung</LblBoQ>
        <Date>2026-07-14</Date>
        <OutlCompl>AllTxt</OutlCompl>
        <BoQBkdn>
          <Type>Item</Type>
          <Length>1</Length>
          <Num>Yes</Num>
        </BoQBkdn>
        <LblTime>Stunden</LblTime>
      </BoQInfo>
      <BoQBody>
        <Itemlist>
          <Item ID="ID243" RNoPart="1">
            <Qty>1.000</Qty>
            <QU>Stk</QU>
            <Description>
              <CompleteText>
                <DetailTxt>
                  <Text>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Round zinc die-cast luminaire for general lighting and illumination of escape and rescue routes according to DIN EN 60598-1, DIN EN 60598-2-22 and DIN EN 1838.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">In robust construction and timeless design, suitable for indoor and outdoor use. The emergency LED can be folded out without tools during installation, e.g. for wall mounting to provide optimum illumination of escape and rescue routes. Available in anthracite.Monitoring: With integrated monitoring module with 20-digit addressing switch, for operation on a central power supply system. Automatic test system according to DIN EN 62034 type ER, in connection with a system of type MultiControl. Functions must be complied with:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Integrated individual luminaire monitoring</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Integrated luminaire manager function</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Individual switchability in conjunction with RP ELS - central power supply system</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Material: Zinc die-cast</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Color: RAL 7016</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Diameter: 363 mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Mounting method: Universal</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Protection class: 1</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Protection rating (IP): IP 54</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Impact restistence rate IK: IK 10</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Allowed temperature DS: -5 °C to 40 °C °C</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Allowed temperature BS: -5 °C to 40 °C °C</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Pictogram: Nein</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Power maintained mode: 17,5 W W</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Power non-maintained mode: 2 W W</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Luminous Flux Emergency Operation: 1600 lm lm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Input voltage AC: 230 V V</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Connection terminals: 1.5 mm² mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Battery: Article number: QCW009ML-AZ-BM</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Accessories:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Brand: RP-Technik GmbH</span>
</p>
                  </Text>
                </DetailTxt>
                <OutlineText>
                  <OutlTxt>
                    <TextOutlTxt>
                      <p style="text-align:left;">
                        <span style="font-family:'Arial';font-size:10pt;">QCW009ML-AZ-BM</span>
                      </p>
                    </TextOutlTxt>
                  </OutlTxt>
                </OutlineText>
              </CompleteText>
            </Description>
          </Item>
        </Itemlist>
      </BoQBody>
    </BoQ>
  </Award>
</GAEB>
