<?xml version="1.0" standalone="no"?>
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA81/3.2">
  <GAEBInfo>
    <Version>3.2</Version>
    <VersDate>2013-10</VersDate>
    <Date>2026-07-22</Date>
    <Time>14:33:52</Time>
    <ProgSystem>RP-Group PIM-System</ProgSystem>
    <ProgName>PIM GAEB-Konverter 1.0</ProgName>
  </GAEBInfo>
  <PrjInfo>
    <NamePrj>Prj-Name</NamePrj>
    <LblPrj>Projektbezeichnung</LblPrj>
    <Descrip>
      <p style="text-align:left;">
        <span style="font-family:'Arial';font-size:10pt;">Projektbeschreibung</span>
      </p>
    </Descrip>
    <Cur>EUR</Cur>
    <CurLbl>Euro</CurLbl>
    <UPFracDig>2</UPFracDig>
  </PrjInfo>
  <Award>
    <DP>81</DP>
    <AwardInfo>
      <Cur>EUR</Cur>
      <CurLbl>Euro</CurLbl>
    </AwardInfo>
    <BoQ ID="ID242">
      <BoQInfo>
        <Name>LV-Name</Name>
        <LblBoQ>LV-Bezeichnung</LblBoQ>
        <Date>2026-07-22</Date>
        <OutlCompl>AllTxt</OutlCompl>
        <BoQBkdn>
          <Type>Item</Type>
          <Length>1</Length>
          <Num>Yes</Num>
        </BoQBkdn>
        <LblTime>Stunden</LblTime>
      </BoQInfo>
      <BoQBody>
        <Itemlist>
          <Item ID="ID243" RNoPart="1">
            <Qty>1.000</Qty>
            <QU>Stk</QU>
            <Description>
              <CompleteText>
                <DetailTxt>
                  <Text>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">LED safety luminaire for illuminating escape and rescue routes in accordance with DIN EN 60598-1, DIN EN 60598-2-22 and DIN EN 1838.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Robust surface-mounted wall luminaire made of die-cast zinc for illuminating escape and rescue routes. Suitable for indoor and outdoor use, e.g. above exits. Optimum light distribution and illumination of escape and rescue routes is achieved through the diffuser lenses incorporated in the luminaire.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Available in white and anthracite. </span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Properties:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Mechanically robust and corrosion resistant</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Powder-coated surface</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Precise edges and straight lines</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- No weld seams and bending edges</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">- Screws concealed and not visible from the frontMonitoring: Version with automatic test system in accordance with DIN EN 62034 type S including SelfControl test button:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Test results with fault analysis (illuminant, charge and battery circuit) and status displays (operation, function test, continuous function test) using 3 colour LEDs</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Automatic function test (weekly)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Automatic continuous function test (every 12 months)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Automatic charge monitoring</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Deep discharge protection with restart inhibit</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Idling and short-circuit shutdown of inverter</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Material: Zinc die-cast</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Color: RAL 9003</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Dimensions: 315 mm x 65 mm x 140 mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Mounting method: Wandaufbau</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Protection class: 1</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Protection rating (IP): IP 65</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Impact restistence rate IK: IK 8</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Allowed temperature DS: -5 °C to 35 °C °C</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Allowed temperature BS: -5 °C to 40 °C °C</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Pictogram: Nein</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Power maintained mode: 3,3 W W</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Power non-maintained mode: 1 W W</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Luminous Flux Emergency Operation: 190 lm lm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Input voltage AC: 230 V V</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Connection terminals: 2.5 mm² mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Battery: LFP3233.01, {{Produkt - BatteryPerformance - BatteryTechnology (P:17:110)}} Battery</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Article number: ZAW011SC</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Accessories:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Brand: RP-Technik GmbH</span>
</p>
                  </Text>
                </DetailTxt>
                <OutlineText>
                  <OutlTxt>
                    <TextOutlTxt>
                      <p style="text-align:left;">
                        <span style="font-family:'Arial';font-size:10pt;">ZAW011SC</span>
                      </p>
                    </TextOutlTxt>
                  </OutlTxt>
                </OutlineText>
              </CompleteText>
            </Description>
          </Item>
        </Itemlist>
      </BoQBody>
    </BoQ>
  </Award>
</GAEB>