<?xml version="1.0" standalone="no"?>
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA81/3.2">
  <GAEBInfo>
    <Version>3.2</Version>
    <VersDate>2013-10</VersDate>
    <Date>2026-07-15</Date>
    <Time>05:15:11</Time>
    <ProgSystem>RP-Group PIM-System</ProgSystem>
    <ProgName>PIM GAEB-Konverter 1.0</ProgName>
  </GAEBInfo>
  <PrjInfo>
    <NamePrj>Prj-Name</NamePrj>
    <LblPrj>Projektbezeichnung</LblPrj>
    <Descrip>
      <p style="text-align:left;">
        <span style="font-family:'Arial';font-size:10pt;">Projektbeschreibung</span>
      </p>
    </Descrip>
    <Cur>EUR</Cur>
    <CurLbl>Euro</CurLbl>
    <UPFracDig>2</UPFracDig>
  </PrjInfo>
  <Award>
    <DP>81</DP>
    <AwardInfo>
      <Cur>EUR</Cur>
      <CurLbl>Euro</CurLbl>
    </AwardInfo>
    <BoQ ID="ID242">
      <BoQInfo>
        <Name>LV-Name</Name>
        <LblBoQ>LV-Bezeichnung</LblBoQ>
        <Date>2026-07-15</Date>
        <OutlCompl>AllTxt</OutlCompl>
        <BoQBkdn>
          <Type>Item</Type>
          <Length>1</Length>
          <Num>Yes</Num>
        </BoQBkdn>
        <LblTime>Stunden</LblTime>
      </BoQInfo>
      <BoQBody>
        <Itemlist>
          <Item ID="ID243" RNoPart="1">
            <Qty>1.000</Qty>
            <QU>Stk</QU>
            <Description>
              <CompleteText>
                <DetailTxt>
                  <Text>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Exit sign in accordance with DIN EN 60598-1, DIN EN 60598-2-22 and DIN EN 1838.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Slim, elegant, convex plastic light that is inclined towards the viewer and tapers symmetrically downwards. For universal mounting (wall*/ceiling), suitable for permanent or standby operation.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">The screwed cover ensures stability and a high IP protection class, while the functional technology remains unobtrusive and no screws are visible from the outside. The pictograms are inside and are inserted solvent-free for one- or two-sided labeling.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Planning security is provided by the tool-free, variable use of the pictograms on site. The pictograms in accordance with DIN ISO 7010 (2x man in the door and two arrows) are included as standard.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">*with additional adapterMonitoring: With integrated monitoring module with 20-digit addressing switch, for operation on a central power supply system. Automatic test system according to DIN EN 62034 type ER, in connection with a system of type MultiControl. Functions must be complied with:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Integrated individual luminaire monitoring</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Integrated luminaire manager function</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Individual switchability in conjunction with RP ELS - central power supply system</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Material: PCABS,Polycarbonate</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Color: RAL 9003</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Dimensions: 73 mm x 339 mm x 211 mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Mounting method: Deckenaufbau</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Protection class: 2</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Protection rating (IP): IP 65</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Impact restistence rate IK: IK 6</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Allowed temperature DS: -20 °C to 40 °C °C</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Allowed temperature BS: -20 °C to 40 °C °C</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Viewing distance: 30m m</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Pictogram: Set</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Power maintained mode: 5,2 W W</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Power non-maintained mode: 1,1 W W</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Luminous Flux Emergency Operation: 335 lm lm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Input voltage AC: 230 V V</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Connection terminals: 2.5 mm² mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Battery: Article number: PXD019ML</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Accessories:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Article number: PXD-AW, wall-parallel-bracket for the luminaire type  PXD</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Article number: PXD-PIKTOSETSONDER.01, Set consists of:  2x Rolli (R&L)  2x Arrow oblique</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Brand: RP-Technik GmbH</span>
</p>
                  </Text>
                </DetailTxt>
                <OutlineText>
                  <OutlTxt>
                    <TextOutlTxt>
                      <p style="text-align:left;">
                        <span style="font-family:'Arial';font-size:10pt;">PXD019ML</span>
                      </p>
                    </TextOutlTxt>
                  </OutlTxt>
                </OutlineText>
              </CompleteText>
            </Description>
          </Item>
        </Itemlist>
      </BoQBody>
    </BoQ>
  </Award>
</GAEB>
