<?xml version="1.0" standalone="no"?>
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA81/3.2">
  <GAEBInfo>
    <Version>3.2</Version>
    <VersDate>2013-10</VersDate>
    <Date>2023-12-11</Date>
    <Time>16:11:56</Time>
    <ProgSystem>RP-Group PIM-System</ProgSystem>
    <ProgName>PIM GAEB-Konverter 1.0</ProgName>
  </GAEBInfo>
  <PrjInfo>
    <NamePrj>Prj-Name</NamePrj>
    <LblPrj>Projektbezeichnung</LblPrj>
    <Descrip>
      <p style="text-align:left;">
        <span style="font-family:'Arial';font-size:10pt;">Projektbeschreibung</span>
      </p>
    </Descrip>
    <Cur>EUR</Cur>
    <CurLbl>Euro</CurLbl>
    <UPFracDig>2</UPFracDig>
  </PrjInfo>
  <Award>
    <DP>81</DP>
    <AwardInfo>
      <Cur>EUR</Cur>
      <CurLbl>Euro</CurLbl>
    </AwardInfo>
    <BoQ ID="ID242">
      <BoQInfo>
        <Name>LV-Name</Name>
        <LblBoQ>LV-Bezeichnung</LblBoQ>
        <Date>2023-12-11</Date>
        <OutlCompl>AllTxt</OutlCompl>
        <BoQBkdn>
          <Type>Item</Type>
          <Length>1</Length>
          <Num>Yes</Num>
        </BoQBkdn>
        <LblTime>Stunden</LblTime>
      </BoQInfo>
      <BoQBody>
        <Itemlist>
          <Item ID="ID243" RNoPart="1">
            <Qty>1.000</Qty>
            <QU>Stk</QU>
            <Description>
              <CompleteText>
                <DetailTxt>
                  <Text>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">MultiControl MCW</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Central battery system MC according to EN 50171 and BGV A3 for the power supply of safety and escape route luminaires 230V / 216V AC/DC. Suitable for emergency lighting systems according to DIN VDE 0100-718, DIN EN 50172 and E DIN VDE 0108-100. With automatic testing device and single luminaire monitoring with individual state indication per luminaire in the control unit in combination with system-oriented electronic ballasts including monitoring module without additional data line. </span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">rated operating time: 	... h</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">recharging time:   	12 h</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">consisting of:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">microprocessor-based control unit with DB25-Centronics printer interface as well as integrated IO-module for the retransmission of operating states, remote initiation of function tests and blocking of the emergency lighting.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">charger module with microprocessor-controlled charging and the number of charging units, necessary for a battery charging in comliance with the standards.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">For the integration of up to 24 variable circuit modules, 3 charger modules (à 2,5A) and max. 1 fuse-protected battery and mains output for sub-systems and sub-distributins.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Larger system configurations require additional marshalling panels or bigger electronics cabinets.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">fuse switch disconnector (NH/D02) for mains and battery supply, terminal cross-section by default 16mm² (larger cross-sections 35mm²/50mm²/70mm² upon request).</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">steel sheet wall-mounted cabinet</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">dimensions: 	H=900mm, W=600mm, D=450mm</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">protection level: 	electronics cabinet IP 20, 	protection class I</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">cable entry:	from top or bottom</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">door hinges:	left (also right possible), 3x double 	bit locking</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">version: 	with 4 wall holders or screwed to 	the battery cabinet (H900mm)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">outside finishing: 	structural powder coating,</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">colour: 	RAL 7035 light grey.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">fitted with:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">freely programmable end circuits à 3A nominal current / 650VA (fuse protection 2x T5A)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">freely programmable end circuits à 4A nominal current / 850VA (fuse protection 2x T6.3A)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">freely programmable end circuits à 6A nominal current / 1,300VA (fuse protection 2x T10A)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">2-pole fuse protection as well as info-pushbutton on the front panel.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">SAM24 light switch queries for the joint switching of general and emergency lighting, with 8 switch inputs (loosely enclosed).</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">LUAN1 potential-free fan contact for the connection of a technical ventilation of the operating room, designed for max. 6A/AC1 fuse-protected with T3,15A connected to terminals.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">LUAN2 fan contact 230V/50Hz for the connection of a technical ventilation of the operating room, fuse-protected with T3,15A connected to terminals.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">LUAN3 3-phase fan contact incl. switch contactor and motor-protecting circuit (T1A) for the connection of a technical ventilation of the operating room, fuse-protected and connected to terminals.</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">LUINT technical ventilation by means of a forced ventilation 230V/50Hz incl. integrated airflow monitor (function monitoring according to EN50171), potential-free, connected to terminals</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">integrated 4-pin event printer MCBD04E</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">built-on transparent door (polycarbonate)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">IP54-design with internal swing frame and transparent door (optional)</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">OGiV – block battery ...... Ah /C10 1.8V/Z, 20°C 216V </span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">(incl. 25% ageing reserve according to EUROBAT and DIN EN 50171) fitted in:</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">battery cabinet, HxWxD 900x600x450mm </span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">with 3 shelves</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">battery cabinet, HxWxD 1,800x600x450mm </span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">with 6 shelves</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">battery rack BGEU I</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">battery rack BGEU II</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">cabinet base, height 100mm, </span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">colour RAL7022 grey</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">cabinet base, height 200mm, </span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">colour RAL7022 grey</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;"></span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">type: MCW348</span>
</p>
<p style="text-align:left;">
<span style="font-family:'Arial';font-size:10pt;">Brand: RP-TechnikBrand: RP-Technik</span>
</p>
                  </Text>
                </DetailTxt>
                <OutlineText>
                  <OutlTxt>
                    <TextOutlTxt>
                      <p style="text-align:left;">
                        <span style="font-family:'Arial';font-size:10pt;">MCUV12</span>
                      </p>
                    </TextOutlTxt>
                  </OutlTxt>
                </OutlineText>
              </CompleteText>
            </Description>
          </Item>
        </Itemlist>
      </BoQBody>
    </BoQ>
  </Award>
</GAEB>